Product Description
Quickly take accurate humidity and temperature to maintain indoor air comfort and quality. Features: Backlit dual display of humidity and temperature 99 record storage capacity Ergonomic design with belt clip and protective holster Fast-setting humidity sensor Low battery indicator Specs: Temperature range: -4° to 140°F (-20° to 60°C) Resolution: 0.1°F (/0.17deg;C) Response time (temperature): 500 ms Relative Humidity range: 5% to 95% RH Humidity Settling Time: 60 seconds Data storage: 99 points Includes 4 AAA alkaline batteries. Complies with EN 61326-1. One-Year Warranty. (Taiwan)
| Price: | $255.17 |
| as of Tue, 05 Mar 2013 02:56:05 GMT ***Remember, deals price on this item for sale just for limited time*** | |
Product Details
- Amazon Sales Rank: #74564 in Home Improvement
- Brand: Fluke
- Model: Fluke-971
- Dimensions: 1.00 pounds
Features
- Quickly take accurate humidity and temperature readings in the air
- Perfect tool for maintenance of facilities and HVAC systems
- Backlit dual display of humidity and temperature
- 99 record storage capacity
- Ergonomic design with belt clip and protective holster
Customer Reviews
Most helpful customer reviews
6 of 6 people found the following review helpful.Simply Amazing Meter
By R. Nottage
This meter is the one. I have reviewed many meters before deciding on this one. Another review says the meter is too slow to respond and that a $3.00 thermometer is as good. Apparently the person does not know that a hygrometer is slower to respond. It's is so much quicker than a sling psychrometer and also no need to take out the Psych Chart to calc dew point. The unit provides a wealth of information quickly and 99 storage registers for readings. Great for balancing, system cooling performance evaluation, diagnostic tool, verification of tstat humidity reading, etc... Have I gloated enough, buy it you won't be sorry you spent the money on this unit.
6 of 7 people found the following review helpful.Fluke 971
By Jeff
I am an HVAC contractor and check condenser charges multipe times a day. My 971 is off by 4.7 degrees on dry bulb and I now question if the wet bulb reading is correct. I have owned this meter for less that 2 years and I am displeased that it has gotten out of calibration or the capacitance sensor is out all ready. I sent Fluke an email asking what the cost of repair is, have not gotten a reply yet. I must buy another for my business and cannot wait for the time span of repair. I am looking at an Extech RH350. I thought fluke was more dependable and reliable, but i was wrong.
5 of 6 people found the following review helpful.not happy
By Tobias Ralph Boisvert
i am a hvac contractor.
i bought this a year or so ago through a wholesale hvac shop. i started having doubts about it bcs i use several fluke 50/2s and a 922 all at the same time and the 971 is always off by five or more degrees. i only use it for wb but like the other reviewer im not sure its correct as the temp is way off when all meters are compared at the same location. i usually get them all normalized for 15 minutes or so in the same place to get them on the same plane. i even compaired them all with the k couple on my digital manifold (mastercool) and all jive but the 971? if this was a cheap meter i would say "man i wished i had bought a fluke". guess again.....
No comments: